image

RFID Glass Tube Transponder

Glass Tube RFID Tag: Implantable Design
Operating Frequency: LF 134.2 kHz; Supports ISO 11784/11785
Medical-Grade Glass Material: Biocompatible, Safe, and Reliable
Ultra-Compact Size: Suitable for Implantation into Animals
Ideal for Permanent Pet Identification
• Lead Time: 5-7 days for in-stock products; 10-12 days for products not in stock. • DPP-Compatible RFID tags
Product Description

RFID Glass Tube Transponder for Animal and Industrial Identification

RFID Glass Tube Transponders are passive identifying devices that have no battery and are embedded within a hermetically sealed glass capsule. The units are equipped with an IC chip and a copper wire antenna and operate at 134.2 kHz in accordance with ISO 11784/11785. The bio-glass housing is resistant to bodily fluids, diluted acids and repeated autoclave sterilisation at 134 °C. These transponders are intended for those conditions where plastic tags are likely to deteriorate or malfunction, for implantation under the skin of animals, and for embedding within industrial components. WS RFID has been manufacturing glass tube transponders since 2008.

What Is an RFID Glass Tube Transponder?

The RFID Glass Tube Transponders is a small, passive RFID device, sealed hermetically in a glass capsule. The encapsulating substance, usually a specific bio-glass such as Schott 8625, a borosilicate glass designed for biological implant applications, resists fluids and chemical erosion, so it’s dependable in conditions where plastic or epoxy-coated tags fail.

The IC and the copper wire antenna are enclosed together in a vacuum to form a corrosion-resistant unit that can work through biological tissue, corrosive liquids, and high-temperature industrial processes without an external power supply.

The cylindrical glass body also exhibits high resistance to compressive stresses, enabling subcutaneous insertion and over-molding into plastic components during injection moulding.

Key Technical Specifications

Parameter Details
Encapsulation Medical-Grade Glass Tube (e.g., Bio-Glass Schott 8625)
Operating Frequency 134.2 kHz (LF)
Protocol Standard ISO 11784 / ISO 11785
Communication Mode FDX-B (Full Duplex) / HDX (Half Duplex)
Form Factor 1.25 × 7 mm to 4 × 32 mm
Installation Method Implantable / Over-moldable / Embedded
Operating Temperature −25°C to +125°C
Protection Rating IP68 / IP69K
Anti-Migration Coating Parylene
Power Source Passive (no battery required)
Rated Lifespan 20+ years

Design Characteristics

No battery, no maintenance

These transponders have no internal battery, but are powered by the magnetic field of the reader. Once implanted or embedded, they have no regular maintenance or replacement over their rated life.

Compact footprint

The smallest size available is 1.25 by 7 mm. This enables for subcutaneous injection with minimum tissue damage and inconspicuous implantation into industrial components without compromising structural integrity.

Bio-glass case study

The Schott 8625 bio-glass is resistant to bodily fluids, diluted acids and most industrial chemicals. It can resist many steam sterilisation cycles at 134°C, which is the normal autoclave temperature used in veterinary and laboratory environments.

application

Application Areas

Pet and livestock identification

The transponder is injected subcutaneously and offers a lifetime ID that is linked to a centralised registry. Veterinary clinics and animal shelters pull the identity information at the time of scan. For large-scale livestock operations, HDX tags provide a longer read range and more resilience to RF interference at automated gate readers.

Tracking Industrial Parts

Glass tube transponders are encapsulated in plastic components or incorporated in tools using an over-molding injection moulding method. They are able to endure the pressures, temperatures and degreasing chemicals characteristic in manufacturing, allowing for long-term part identification throughout the production life cycle.

Medical & Laboratory Asset Management

These transponders are used to monitor glass vials, surgical equipment and high value specimens in healthcare and research procedures, since they can resist cryogenic storage temperatures and regular steam sterilisation.

equipment

Quality Control

Before shipping, every batch of glass tube transponders manufactured by WS RFID go through a multi-stage testing process.

  • Vacuum leakage testing verifies that the hermetic seal of each glass capsule is intact.
  • Frequency consistency is tested using network analysers to make sure each tag is within ±3 kHz of the 134.2 kHz central frequency.
  • Thermal Cycle Testing – Cycles units from -40°C to +120°C to verify glass integrity under fast temperature change.
  • Biocompatibility testing of implanted tags is performed according to ISO 10993 criteria to determine if the glass body and coating materials are inert under biological circumstances.
  • Range sensitivity investigation for reading tags shows constant performance whether reading tags through organic stuff or liquids.

Service Process

OEM and ODM Customization

WS RFID provides an OEM and ODM collaboration for RFID Glass Tube Transponders projects. Before manufacturing, the team will evaluate reader compatibility requirements, ID format specifications and appropriate regional registry standards.

Supported customisation possibilities include bespoke chip encoding, variable data printing, antenna design changes and package variations for implantation kits. All customisation is done in-house.

  • MOQ:500pcs
  • Lead time: 5-7 business days (in stock)
  • Custom or out of stock configurations: 10-12 business days
  • Available Samples: Available at no cost
  • Sample Terms: Open to negotiation

certificate

FAQ

Q1: What is the difference between FDX-B and HDX ?

A: FDX-B (Full Duplex) is the pet identification standard protocol. It is less expensive per-unit and more compatible with commercial scanners. HDX ( Half Duplex ) has a greater read range and improved resistance to RF interference . This makes it suitable for large scale livestock operations and automated industrial gate readers.

Q2: Are these transponders autoclave sterilisable?

A: Yup. The bio-glass housing is able to endure many cycles of steam sterilisation at 134°C, the regular temperature of the autoclave used in veterinary clinics, hospitals, and laboratories.

Q3: What is the strength of the glass capsule when it is mechanically installed?

A: It’s the shape of the cylinder that resists compression. Do not allow mechanical installation to subject the ends of the capsule to direct impact stress.

Q4: Can the products be read through metal?

A: No. Metal surfaces will impede the LF RF signal. When installing a tag on a metal asset, it must be mounted within a pre-drilled hole with a non-metallic spacer or filler to ensure read function.

Q5: Do these transponders need a battery?

A: No. They are completely passive gadgets. The operating power is obtained from the magnetic field of the reader.

Q6: What biocompatibility measures are used for implanted tags?

A: Tags for implantation are tested to ISO 10993 biocompatibility criteria. The Parylene anti-migration coating aids in preventing migration inside tissue and the bio-glass substance is chemically inert to physiological fluids and most diluted chemical solutions.

Contact Us

Have a project or need a sample with an RFID Glass Tube Transponder? Reach us at kenny@w-srfid.com — we typically respond within one business day.

Drop Us A Line
RFID smart cards, wristbands, and electronic tags for identification, access control, and tracking applications. Contact us with your application, reader details, quantity, and customization requirements to discuss product options and sample availability.
Welcome to contact us anytime for more products contact us