image

UHF On-Metal Tag

• Product Type: Anti-metal RFID tag, designed specifically for intelligent industrial applications.
• Chip Technology: Industrial-grade chip solution, operating frequency UHF 860-960MHz.
• Communication Protocol: Supports EPC Gen2, specifically designed for metal surfaces, providing stable reading performance.
• Environmental Adaptability: performance on metal surfaces, long reading distance, meeting industrial application requirements. • DPP-Compatible RFID tags
• Materials and Processes: Special ceramics or plastics with an insulating layer, industrial-grade durable design.
• Customization Services: Supports customized sizes, installation methods, and environmental adaptability.
• Company Advantages: WS RFID provides industrial solutions from tag design to system integration.
• Quality Certifications: Certified with industrial-grade standards, RoHS, REACH, IP protection rating, etc.
• Lead Time: 5-7 days for in-stock products; 10-12 days for products not in stock.
• Application Value: Enables production automation, improves production efficiency, and reduces operating costs.
Product Description

UHF On-Metal Tag for Industrial Asset Tracking | Stable Reading on Any Metal Surface

Standard RFID labels go dead as soon as they contact metal. WS RFID’s UHF On-Metal Tag addresses this issue with an integrated insulating layer and PIFA-style antenna, offering a read range of 0.5-8 meters directly on steel, aluminium and other conductive surfaces. The reader operates at 860-960 MHz and uses EPC Gen2 protocol. It is temperature tolerant from -40°C to +250°C and has an IP rating from IP54 to IP68. It is ideal for metal processing, automobile manufacturing, logistics and other harsh industrial situations.

What Is a UHF On-Metal Tag?

A normal RFID tag on metal will reflect the radio waves back into the antenna, cancelling the signal and making accurate reading impossible. This is a physics problem that is widely documented and not a reader or software problem.

This is solved at the hardware level using a UHF On-Metal Tag. The antenna is physically separated from the metal substrate by an insulating spacer of ceramic or engineering plastic. A PIFA (Planar Inverted-F Antenna) shape is used in certain designs, which further minimises susceptibility to the underlying conductive surface.

WS RFID’s on-metal tags are constructed using industrial-grade chips from the Impinj Monza, Alien Higgs and NXP UCODE families, and are encased in ceramic or high-density plastic enclosures designed for sustained industrial usage.

Technical Specifications

Parameter Specification
Operating Frequency UHF 860–960 MHz
Communication Protocol EPC Gen2 / ISO 18000-6C
Read Distance 0.5–8 meters
EPC Storage 96-bit / 128-bit / 512-bit; user area optional
Ambient Temperature -40°C to +85°C (high-temp models up to +250°C)
Protection Rating IP54 / IP65 / IP67 / IP68 (model-dependent)
Material Special ceramics or engineering plastics with insulating layer
Chip Options Impinj Monza, Alien Higgs, NXP UCODE
Mounting Methods Screw fixing, riveting, welding, embedded
Size Multiple industrial standard sizes; custom dimensions supported
MOQ 500 units
Lead Time 5–7 days (in stock); 10–12 days (production order)

Product Advantages

Stable Signal on Conductive Surfaces

The insulator layer and antenna shape maintain the signal performance when the tag is flat placed on steel or aluminium. The read range is consistent with the 0.5–8 metre standard independent of the substrate, subject to reader output power and site circumstances.

Wide Operating Temperature

Standard versions range from -40°C to +85°C. High temperature versions go to +250°C and are used in paint ovens, welding areas, autoclaves and other heat intense procedures.

IP protection flexibility

Available in IP54, IP65, IP67 and IP68 variants. Units with an IP68 rating are certified for complete immersion and recommended for wash-down stations, chemical processing settings and outdoor storage.

Chip & Memory Options

We have Impinj Monza, Alien Higgs and NXP UCODE chips available, enabling you to match the tag to your current reader infrastructure. EPC memory spans from 96-bit to 512-bit. There is optional user memory to encode extra asset data.

Support for batch reading

The EPC Gen2 protocol permits reading many tags at a time. When used with a stationary UHF reader, the tag may be detected in a batch scan at up to 8 meters, avoiding the requirement for individual item-level scans on busy production lines.

application

Application Scenarios

UHF On-Metal Tags are used in circumstances where contact with metal is inevitable and the reliability of reading is important:

  • Metal processing Tracking steel plates, aluminium sheets and copper stock through phases of manufacturing
  • Automotive Manufacturing – Body panels, chassis pieces and engine components on the manufacturing line identification
  • Machinery and Equipment - Labelling machine tools and injection moulding equipment for maintenance scheduling
  • Logistics and Warehousing Mounting on metal racks, pallets and shipping containers for inventory control
  • Power Equipment – Transformer, switchgear and cable tray tagging for field service management
  • Construction – Tracking curtain wall components, metal doors and steel structures around project locations
  • Chemical Equipment – Spotting reactors, storage tanks and pipes in corrosive environments
  • Shipbuilding – Supervision of hull sections, deck appliances and outfitting of cabins during ship assembly

equipment

Quality and Certifications

WS RFID has a production facility with Muehlbauer bonding lines and Voyantic Tagformance systems for performance verification. The testing of each batch of manufacturing will be in the following order:

  • Verification of read range and backscatter signal
  • Thermal cycle : -40°C to +85°C
  • Chemical resistance testing for typical industrial fluids
  • EPC memory encoding accuracy evaluation
  • Mechanical stress test for mounting durability

Batch failure rate is controlled within 0.3%. All goods are ISO 9001:2015 certified and comes with 1 year guarantee. Compliance paperwork includes CE, FCC, RoHS, REACH and POPs.

Customization and OEM Options

WS RFID enables the OEM, ODM manufacture of on-metal tags. Among the configurable parameters are:

  • Form factor and dimensions – bespoke sizes for non-standard or space-constrained mounting surfaces
  • Mounting technique – screw holes, rivet points, weld pads or flush integrated designs
  • Chip choices – Impinj, Alien or NXP depending on your reader and software environment
  • IP rating – tailored to the exact exposure circumstances of your location
  • Memory configuration – 96-bit up to 512-bit EPC, user memory optional

Chip pre-encoding and variable data printing are offered. The option is viable for pilot initiatives as well as full-scale deployments, since the MOQ is 500 units.

certificate

System Integration

WS RFID’s product is compatible with MES, ERP and WMS applications using standard EPC Gen2 protocol. The firm offers software SDKs and remote integration help for new installations.

If your team is installing a new line, WS RFID can help with reader location, antenna set-up and tag placement to optimise your efficiency. Custom functional samples are provided within 7 working days to allow for on-site evaluation prior to a complete production order.

Service Process

FAQ

Q1: Will the tag read consistently when completely installed on a steel surface?

A: Yes. The ceramic or plastic insulation layer separates (physically) the antenna from the metal substrate. Under normal circumstances with proper reader output the read range remains within the 0.5-8 metre limit.

Q2: What are the supported mounting methods?

A: Screw fastening, riveting, welding and embedded installation are possible. Your choice will depend on the material of the surface you are attaching to and if you want the tag to be detachable once attached.

Q3: Do you have high temperature models for automotive paint ovens or welding areas?

A: Yes, I am. High temperature versions are available up to +250°C. Standard models are -40° to +85°C.

Q4: Will the tag integrate with our current MES or WMS?

A: Yes. Most of the industrial middleware and most MES, ERP and WMS solutions support EPC Gen2. WS RFID also offers SDK documentation and remote integration support.

Q5: What is the MOQ and how fast can I acquire samples?

A: MOQ 500 pieces. Free samples are offered for standard samples. Functional prototypes usually may be turned out in 7 working days.

Q6: Are there certifications for these tags?

A: ISO 9001:2015 accredited; CE. FCC. RoHS. REACH. POPs compliant. Depending on the model, IP ratings are offered from IP54 to IP68.

Contact Us

Request samples, pricing, or technical support for your UHF On-Metal Tag deployment. Reach our team at kenny@w-srfid.com.

Drop Us A Line
RFID smart cards, wristbands, and electronic tags for identification, access control, and tracking applications. Contact us with your application, reader details, quantity, and customization requirements to discuss product options and sample availability.
Welcome to contact us anytime for more products contact us